Winson Lee
Winson Lee
School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong
Verified email at uow.edu.au - Homepage
Title
Cited by
Cited by
Year
Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking
WCC Lee, LA Frossard, K Hagberg, E Haggstrom, DL Gow, S Gray, ...
Medical Engineering & Physics 30 (7), 825-833, 2008
1632008
Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living
WCC Lee, LA Frossard, K Hagberg, E Haggstrom, R Brånemark, ...
Clinical biomechanics 22 (6), 665-673, 2007
1622007
Load transfer mechanics between trans-tibial prosthetic socket and residual limb—dynamic effects
X Jia, M Zhang, WCC Lee
Journal of biomechanics 37 (9), 1371-1377, 2004
1522004
Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
WCC Lee, M Zhang, X Jia, JTM Cheung
Medical engineering & physics 26 (8), 655-662, 2004
1352004
Evaluation of the Microsoft Kinect as a clinical assessment tool of body sway
LF Yeung, KC Cheng, CH Fong, WCC Lee, KY Tong
Gait & posture 40 (4), 532-538, 2014
1132014
Regional differences in pain threshold and tolerance of the transtibial residual limb: including the effects of age and interface material
WC Lee, M Zhang, AF Mak
Archives of physical medicine and rehabilitation 86 (4), 641-649, 2005
772005
FE stress analysis of the interface between the bone and an osseointegrated implant for amputees–implications to refine the rehabilitation program
WCC Lee, JM Doocey, R Brånemark, CJ Adam, JH Evans, MJ Pearcy, ...
Clinical biomechanics 23 (10), 1243-1250, 2008
762008
Using computational simulation to aid in the prediction of socket fit: A preliminary study
WCC Lee, M Zhang
Medical Engineering & Physics 29 (8), 923-929, 2007
622007
Balance improvement effects of biofeedback systems with state-of-the-art wearable sensors: A systematic review
CZH Ma, DWC Wong, WK Lam, AHP Wan, WCC Lee
Sensors 16 (4), 434, 2016
492016
Finite-element analysis to determine effect of monolimb flexibility on structural strength and interaction between residual limb and prosthetic socket
WCC Lee, M Zhang, D Boone, B Contoyannis
Journal of rehabilitation research and development 41 (6A), 775-786, 2004
482004
Design of monolimb using finite element modelling and statistics-based Taguchi method
WCC Lee, M Zhang
Clinical biomechanics 20 (7), 759-766, 2005
462005
A quasi-dynamic nonlinear finite element model to investigate prosthetic interface stresses during walking for trans-tibial amputees
X Jia, M Zhang, X Li, WCC Lee
Clinical Biomechanics 20 (6), 630-635, 2005
462005
Effectiveness of adjustable dorsiflexion night splint in combination with accommodative foot orthosis on plantar fasciitis
W Lee, WY Wong, E Kung, A Leung
442012
Dynamic impression insole in rheumatoid foot with metatarsal pain
BC Chang, JY Wang, BS Huang, HY Lin, WCC Lee
Clinical Biomechanics 27 (2), 196-201, 2012
352012
Gait analysis of low-cost flexible-shank transtibial prostheses
WCC Lee, M Zhang, PPY Chan, DA Boone
IEEE Transactions on neural systems and rehabilitation engineering 14 (3 …, 2006
292006
Quantifying the regional load-bearing ability of trans-tibial stumps
M Zhang, WCC Lee
Prosthetics and orthotics international 30 (1), 25-34, 2006
282006
Long-distance walking effects on trans-tibial amputees compensatory gait patterns and implications on prosthetic designs and training
LF Yeung, AKL Leung, M Zhang, WCC Lee
Gait & Posture 35 (2), 328-333, 2012
262012
A vibrotactile and plantar force measurement-based biofeedback system: Paving the way towards wearable balance-improving devices
CZH Ma, AHP Wan, DWC Wong, YP Zheng, WCC Lee
Sensors 15 (12), 31709-31722, 2015
222015
Regulation of HAS expression in human synovial lining cells of TMJ by IL-1β
J Li, X Long, J Ke, QG Meng, WCC Lee, JM Doocey, F Zhu
archives of oral biology 53 (1), 60-65, 2008
222008
Wearable vibrotactile biofeedback device allowing identification of different floor conditions for lower-limb amputees
AH Wan, DW Wong, CZ Ma, M Zhang, WC Lee
Archives of physical medicine and rehabilitation 97 (7), 1210-1213, 2016
192016
The system can't perform the operation now. Try again later.
Articles 1–20