Follow
Lutz Heinemann
Lutz Heinemann
Unknown affiliation
Verified email at profil.com
Title
Cited by
Cited by
Year
Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range
T Battelino, T Danne, RM Bergenstal, SA Amiel, R Beck, T Biester, E Bosi, ...
Diabetes care 42 (8), 1593-1603, 2019
28782019
International consensus on use of continuous glucose monitoring
T Danne, R Nimri, T Battelino, RM Bergenstal, KL Close, JH DeVries, ...
Diabetes care 40 (12), 1631-1640, 2017
18962017
Lower within-subject variability of insulin detemir in comparison to NPH insulin and insulin glargine in people with type 1 diabetes
T Heise, L Nosek, BB Rønn, L Endahl, L Heinemann, C Kapitza, ...
Diabetes 53 (6), 1614-1620, 2004
8652004
Definition, classification and diagnosis of diabetes mellitus
A Petersmann, D Müller-Wieland, UA Müller, R Landgraf, M Nauck, ...
Experimental and Clinical Endocrinology & Diabetes 127 (S 01), S1-S7, 2019
7262019
Time-action profile of the long-acting insulin analog insulin glargine (HOE901) in comparison with those of NPH insulin and placebo.
L Heinemann, R Linkeschova, K Rave, B Hompesch, M Sedlak, T Heise
Diabetes care 23 (5), 644-649, 2000
6362000
Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
RM Bergenstal, RW Beck, KL Close, G Grunberger, DB Sacks, A Kowalski, ...
Diabetes care 41 (11), 2275-2280, 2018
5502018
Sensors for glucose monitoring: technical and clinical aspects
T Koschinsky, L Heinemann
Diabetes/metabolism research and reviews 17 (2), 113-123, 2001
5282001
Home use of an artificial beta cell in type 1 diabetes
H Thabit, M Tauschmann, JM Allen, L Leelarathna, S Hartnell, ...
New England Journal of Medicine 373 (22), 2129-2140, 2015
5072015
Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin …
L Heinemann, G Freckmann, D Ehrmann, G Faber-Heinemann, S Guerra, ...
The Lancet 391 (10128), 1367-1377, 2018
4862018
Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study
S Martin, B Schneider, L Heinemann, V Lodwig, HJ Kurth, H Kolb, ...
Diabetologia 49, 271-278, 2006
4632006
Smoking is associated with progression of diabetic nephropathy
PT Sawicki, U Didjurgeit, I Mühlhauser, R Bender, L Heinemann, ...
Diabetes care 17 (2), 126-131, 1994
4141994
First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
A Caduff, E Hirt, Y Feldman, Z Ali, L Heinemann
Biosensors and Bioelectronics 19 (3), 209-217, 2003
3662003
Variability of insulin absorption and insulin action
L Heinemann
Diabetes technology & therapeutics 4 (5), 673-682, 2002
3542002
Continuous glucose monitoring with glucose sensors: calibration and assessment criteria
V Lodwig, L Heinemann
Diabetes Technology & Therapeutics 5 (4), 572-586, 2003
3412003
Diabetes digital app technology: benefits, challenges, and recommendations. A consensus report by the European Association for the Study of Diabetes (EASD) and the American …
GA Fleming, JR Petrie, RM Bergenstal, RW Holl, AL Peters, L Heinemann
Diabetes care 43 (1), 250-260, 2020
3112020
Comparison of the numerical and clinical accuracy of four continuous glucose monitors
B Kovatchev, S Anderson, L Heinemann, W Clarke
Diabetes care 31 (6), 1160-1164, 2008
3092008
Correlation between blood glucose concentration in diabetics and noninvasively measured tissue optical scattering coefficient
JT Bruulsema, JE Hayward, TJ Farrell, MS Patterson, L Heinemann, ...
Optics letters 22 (3), 190-192, 1997
2871997
Insulin pump risks and benefits: a clinical appraisal of pump safety standards, adverse event reporting, and research needs: a joint statement of the European Association for …
L Heinemann, GA Fleming, JR Petrie, RW Holl, RM Bergenstal, AL Peters
Diabetes care 38 (4), 716-722, 2015
2612015
Prevalence of renal artery stenosis in diabetes mellitus—an autopsy study
PT Sawicki, S Kaiser, L Heinemann, H Frenzel, M Berger
Journal of internal medicine 229 (6), 489-492, 1991
2361991
Time-action profile of inhaled insulin in comparison with subcutaneously injected insulin lispro and regular human insulin
K Rave, S Bott, L Heinemann, S Sha, RHA Becker, SA Willavize, T Heise
Diabetes care 28 (5), 1077-1082, 2005
2302005
The system can't perform the operation now. Try again later.
Articles 1–20