Wspomagana komputerowo statystyczna analiza wyników badań M Dobosz Akademicka Oficyna Wydawnicza EXIT, 2004 | 350 | 2004 |
Metrological feasibilities of CMM touch trigger probes. Part I: 3D theoretical model of probe pretravel A Woźniak, M Dobosz Measurement 34 (4), 273-286, 2003 | 109 | 2003 |
Methods for the calibration of vibration pick-ups by laser interferometry: I. Theoretical analysis M Dobosz, T Usuda, T Kurosawa Measurement Science and Technology 9 (2), 232, 1998 | 63 | 1998 |
Metrological feasibilities of CMM touch trigger probes: Part II: Experimental verification of the 3D theoretical model of probe pretravel M Dobosz, A Woźniak Measurement 34 (4), 287-299, 2003 | 61 | 2003 |
Influence of measured objects parameters on CMM touch trigger probe accuracy of probing A Woźniak, M Dobosz Precision Engineering 29 (3), 290-297, 2005 | 59 | 2005 |
CMM touch trigger probes testing using a reference axis M Dobosz, A Woźniak Precision Engineering 29 (3), 281-289, 2005 | 55 | 2005 |
Factors influencing probing accuracy of a coordinate measuring machine A Wozniak, M Dobosz IEEE Transactions on Instrumentation and Measurement 54 (6), 2540-2548, 2005 | 48 | 2005 |
The influence of social support from the family on health related-quality of life in persons with a colostomy M Leyk, J Ksiazek, A Habel, M Dobosz, A Kruk, S Terech Journal of Wound Ostomy & Continence Nursing 41 (6), 581-588, 2014 | 37 | 2014 |
High-resolution laser linear encoder with numerical error compensation M Dobosz Optical Engineering 38 (6), 968-973, 1999 | 37 | 1999 |
Overview of the laser-wavelength measurement methods M Dobosz, M Kożuchowski Optics and Lasers in Engineering 98, 107-117, 2017 | 33 | 2017 |
Optical profilometer: a practical approximate method of analysis M Dobosz Applied optics 22 (24), 3983-3987, 1983 | 32 | 1983 |
Methods for the calibration of vibration pick-ups by laser interferometry: II. Experimental verification M Dobosz, T Usuda, T Kurosawa Measurement Science and Technology 9 (2), 240, 1998 | 29 | 1998 |
The methods for the calibration of vibration pick-ups by laser interferometry: part III. Phase-lag evaluation T Usuda, M Dobosz, T Kurosawa Measurement Science and Technology 9 (10), 1672, 1998 | 28 | 1998 |
Application of a divergent laser beam in a grating interferometer for high-resolution displacement measurements M Dobosz Optical Engineering 33 (3), 897-901, 1994 | 24 | 1994 |
Interference method for ultra-precision measurement and compensation of laser beam angular deflection M Dobosz, O Iwasinska-Kowalska Applied optics 53 (1), 111-122, 2014 | 23 | 2014 |
Interference fringe detection system for distance measuring interferometer M Dobosz, G Zamiela Optics & Laser Technology 44 (5), 1620-1628, 2012 | 21 | 2012 |
Double wedge prism based beam deflector for precise laser beam steering K Tyszka, M Dobosz, T Bilaszewski Review of Scientific Instruments 89 (2), 2018 | 18 | 2018 |
A new method of non-contact gauge block calibration using a fringe-counting technique: I. Theoretical basis M Dobosz, O Iwasinska-Kowalska Optics & Laser Technology 42 (1), 141-148, 2010 | 18 | 2010 |
A new method of noncontact gauge block calibration using the fringe counting technique: II. Experimental verification O Iwasinska-Kowalska, M Dobosz Optics & Laser Technology 42 (1), 149-155, 2010 | 18 | 2010 |
New stylus probe with interferometric transducer for surface roughness and form profiling M Dobosz Optical engineering 33 (3), 902-907, 1994 | 17 | 1994 |