Follow
Dr. Tobias Buehren
Dr. Tobias Buehren
Senior Innovation Manager, Carl Zeiss AG
Verified email at zeiss.com
Title
Cited by
Cited by
Year
Heads-up vision analyzer
C Baker, T Buehren, J Foley
US Patent 9,895,058, 2018
1722018
Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography–based biometer versus partial coherence interferometry and optical low …
KS Kunert, M Peter, M Blum, W Haigis, W Sekundo, J Schütze, T Buehren
Journal of Cataract & Refractive Surgery 42 (1), 76-83, 2016
1592016
Corneal aberrations and reading
T Buehren, MJ Collins, L Carney
Optometry & Vision Science 80 (2), 159-166, 2003
1442003
Near work induced wavefront aberrations in myopia
T Buehren, MJ Collins, LG Carney
Vision Research 45 (10), 1297-1312, 2005
1302005
Accommodation stimulus–response function and retinal image quality
T Buehren, MJ Collins
Vision research 46 (10), 1633-1645, 2006
1212006
The stability of corneal topography in the post-blink interval
T Buehren, MJ Collins, DR Iskander, B Davis, B Lingelbach
Cornea 20 (8), 826-833, 2001
1112001
Corneal topography and accommodation
T Buehren, MJ Collins, J Loughridge, LG Carney, DR Iskander
Cornea 22 (4), 311-316, 2003
1062003
Retinal image quality, reading and myopia
MJ Collins, T Buehren, DR Iskander
Vision research 46 (1-2), 196-215, 2006
1022006
Corneal optics after reading, microscopy and computer work
MJ Collins, T Buehren, A Bece, SC Voetz
Acta Ophthalmologica Scandinavica 84 (2), 216-224, 2006
782006
Control of myopia using contact lenses
M Collins, T Buehren, L Carney, B Davis, DR Iskander, R Franklin, ...
US Patent 8,485,662, 2013
722013
Influence of accommodation on the anterior and posterior cornea
SA Read, T Buehren, MJ Collins
Journal of Cataract & Refractive Surgery 33 (11), 1877-1885, 2007
632007
Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography
N Hirnschall, T Buehren, F Bajramovic, M Trost, T Teuber, O Findl
Journal of Cataract & Refractive Surgery 43 (6), 732-736, 2017
552017
Ocular microfluctuations and videokeratoscopy
T Buehren, BJ Lee, MJ Collins, DR Iskander
Cornea 21 (4), 346-351, 2002
472002
Factors influencing lid pressure on the cornea
MJ Collins, T Buehren, T Trevor, M Statham, J Hansen, DA Cavanagh
Eye & Contact Lens 32 (4), 168-173, 2006
362006
Regression of lid-induced corneal topography changes after reading
MJ Collins, K Kloevekorn-Norgall, T Buehren, SC Voetz, B Lingelbach
Optometry and vision science 82 (9), 843-849, 2005
362005
Potential higher-order aberration cues for sphero-cylindrical refractive error development
T Buehren, MJ COLLINS, B DAVIS
Optometry and Vision Science 84 (3), 163-174, 2007
352007
Pilot evaluation of refractive prediction errors associated with a new method for ray-tracing–based intraocular lens power calculation
N Hirnschall, T Buehren, M Trost, O Findl
Journal of Cataract & Refractive Surgery 45 (6), 738-744, 2019
252019
Agreement between a partial coherence interferometer and 2 manual keratometers
MA Bullimore, T Buehren, W Bissmann
Journal of Cataract & Refractive Surgery 39 (10), 1550-1560, 2013
222013
A refined bootstrap method for estimating the Zernike polynomial model order for corneal surfaces
DR Iskander, MR Morelande, MJ Collins, T Buehren
IEEE transactions on biomedical engineering 51 (12), 2203-2206, 2004
202004
Anti myopia lens
T Buehren
US Patent 9,360,683, 2016
172016
The system can't perform the operation now. Try again later.
Articles 1–20