Follow
Józef Wiora
Józef Wiora
Politechnika Śląska
Verified email at wiora.pl - Homepage
Title
Cited by
Cited by
Year
Evaluation of measurement value and uncertainty of sound pressure level difference obtained by active device noise reduction
J Wiora, S Wrona, M Pawelczyk
Measurement 96, 67-75, 2017
242017
A weighted method for reducing measurement uncertainty below that which results from maximum permissible error
J Wiora, A Kozyra, A Wiora
Measurement Science and Technology 27 (3), 035007, 2016
212016
Measurement uncertainty calculations for pH value obtained by an ion-selective electrode
J Wiora, A Wiora
Sensors 18 (6), 1915, 2018
152018
Influence of methods approximating fractional-order differentiation on the output signal illustrated by three variants of Oustaloup filter
J Wiora, A Wiora
Symmetry 12 (11), 1898, 2020
142020
Towards automation of measurement processes of surface water parameters by a remote-controlled catamaran
J Wiora, A Kozyra, A Wiora
Bulletin of the polish academy of sciences technical sciences, 351-359-351-359, 2017
112017
Improvement of measurement results based on scattered data in cases where averaging is ineffective
J Wiora
Sensors and Actuators B: Chemical 201, 475-481, 2014
112014
Over one-year long-term laboratory tests of pH electrodes in terms of industrial applications checking stabilities of their parameters and their influence on uncertainties of …
A Wiora, J Wiora
Sensors 18 (12), 4102, 2018
102018
Problems and risks occurred during uncertainty evaluation of a quantity calculated from correlated parameters: a case study of pH measurement
J Wiora
Accreditation and Quality Assurance 21 (1), 33-39, 2016
102016
Szacowanie niepewności w pomiarach potencjometrycznych
A Kozyra, A Wiora, J Wiora
PAN, Katowice, 2007
102007
Calibration of potentiometric sensor arrays with a reduced number of standards
A Kozyra, J Wiora, A Wiora
Talanta 98, 28-33, 2012
92012
Comments on “Combined measurements–A way to improve the measurement accuracy of an additive quantity” by R. Siuda and A. Grabowski
J Wiora, A Kozyra, A Wiora
Measurement 46 (7), 2259-2261, 2013
82013
Dynamic models of ion-selective electrodes with their electronic interface
A Wiora, J Wiora, A Kozyra
Metrology and Measurement Systems 13 (4), 421-432, 2006
82006
A system allowing for the automatic determination of the characteristic shapes of ion-selective electrodes
J Wiora, A Wiora
Optoelectronic and Electronic Sensors VI 6348, 82-89, 2006
62006
Least Lp-norm low-pass filter
J Wiora
Automatica 133, 109854, 2021
42021
Errors in Potentiometric Measurements
J Wiora
LAP LAMBERT Academic Publishing, 2011
42011
Measurement uncertainty evaluation of results provided by transducers working in control loops
J Wiora, A Wiora
2018 23rd International Conference on Methods & Models in Automation …, 2018
32018
Uncertainty evaluation of pH measured using potentiometric method
J Wiora
Intelligent Systems' 2014: Proceedings of the 7th IEEE International …, 2015
32015
Comparison of ESP programming platforms
F Rak, J Wiora
Computer science and information technologies 2 (2), 77-86, 2021
22021
Method and system for controlling heating, ventilation and air conditioning
M Borowka, A Kolosowski, M Pawelczyk, A Kozyra, T Grychowski, ...
US Patent App. 16/527,083, 2021
12021
Inaccuracies Revealed During the Analysis of Propagation of Measurement Uncertainty Through a Closed-Loop Fractional-Order Control System
J Wiora, A Wiora
Advances in Non-Integer Order Calculus and Its Applications: Proceedings of …, 2020
12020
The system can't perform the operation now. Try again later.
Articles 1–20