Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy K Kuziemski, J Pieńkowska, W Słomiński, K Specjalski, K Dziadziuszko, ... Diabetes Research and Clinical Practice 91 (1), 80-86, 2011 | 18 | 2011 |
Accuracy of spirometry performed by general practitioners and pneumonologists in the Pomeranian region in the ‘COPD Prevention’NHF programme K Kuziemski, W Słomiński, K Specjalski, E Jassem, R Kalicka, ... Pneumonologia i Alergologia Polska 77, 380-386, 2009 | 17* | 2009 |
Parametric modeling of DSC-MRI data with stochastic filtration and optimal input design versus non-parametric modeling R Kalicka, A Pietrenko-Dąbrowska Annals of Biomedical Engineering 35 (3), 453-464, 2007 | 16 | 2007 |
Obrazowanie parametryczne w badaniach mózgu metodami MRI/PET J Rumiński, R Kalicka, Bobek-Billewicz B. Wydawnictwo Gdańskie, 2006 | 12* | 2006 |
Modelling of spirometry. Diagnostic usefulness of model parameters R Kalicka, W Slominski, K Kuziemski EUROCON 2007-The International Conference on" Computer as a Tool", 2137-2143, 2007 | 10 | 2007 |
Properties of D-optimal sampling schedule for compartmental models R Kalicka, D Bochen Biocybernetics and Biomedical Engeenering 25 (1), 23-36, 2005 | 10 | 2005 |
Ocena przydatności filtracji Kalmana do poprawy właściwości szumowych danych uzyskiwanych w badaniach DSC-MRI mózgu R Kalicka, S Lipiński Pomiary Automatyka Kontrola 54 (3), 118-121, 2008 | 8* | 2008 |
Modelling of diffusing capacity measurement results in lung microangiopathy patients: a novel pulmonary diagnostic support. R Kalicka, W Słomiński, K Kuziemski Methods of Information in Medicine 51 (1), 21-28, 2012 | 7 | 2012 |
A fast method of separation of the noisy background from the head-cross section in the sequence of MRI scans R Kalicka, S Lipiński Biocybern Biomed Eng 30 (2), 15-27, 2010 | 7 | 2010 |
Wykorzystanie wyników modelowania do interpretacji badań spirometrycznych R Kalicka, W Słomiński, K Kuziemski XV Krajowa Konferencja Naukowa Biocybernetyka i Inżynieria Biomedyczna, 125, 2007 | 7* | 2007 |
Modelowanie procesów kinetycznych w systemach biomedycznych. Optymalna identyfikacja modelu. R Kalicka Wydawnictwo Politechniki Gdańskiej, 2000 | 6 | 2000 |
Optimal design and organisation of biomedical experiment R Kalicka Measurement 26 (1), 19-44, 1999 | 5 | 1999 |
Novel method of lung area extraction in chest perfusion computed tomography R Kalicka, S Lipiński, M Browarczyk Biomedizinische Technik/Biomedical Engineering 58 (1), 79-86, 2013 | 4 | 2013 |
Optimal multicompartmental sampling design. Attributes of the main algorithms and all-purpose software R Kalicka IFAC Proceedings Volumes 27 (1), 287-288, 1994 | 4 | 1994 |
Automatic selection of arterial input function in DSC-MRI measurements for calculation of brain perfusion parameters using parametric modelling S Lipiński, R Kalicka Mathematical Modelling of Natural Phenomena 13 (6), 58, 2018 | 3 | 2018 |
Modelling of subarachnoid space width changes in apnoea resulting as a function of blood flow parameters R Kalicka, K Mazur, J Wolf, AF Frydrychowski, K Narkiewicz, ... Microvascular Research 113, 16-21, 2017 | 3 | 2017 |
Modelowanie matematyczne systemów fizjologicznych i farmakokinetycznych dla wspomagania diagnostyki i terapii R Kalicka Akademicka Oficyna Wydawnicza EXIT, 2013 | 3 | 2013 |
Brain perfusion imaging with the use of parametric modelling basing on DSC-MRI data R Kalicka, A Pietrenko-Dabrowska, R Nowicki, S Lipinski Information Technology, 2008. IT 2008. 1st International Conference on, 363-366, 2008 | 3 | 2008 |
Efficiency of new method of removing the noisy background from the sequence of MRI scans depending on structuring elements used to morphological processing R Kalicka, S Lipinski, A Pietrenko-Dąbrowska Information Technology, 2008. IT 2008. 1st International Conference on, 459-462, 2008 | 3 | 2008 |
The modelling of spirometry - the application for diagnostic purposes R Kalicka, W Slominski, K Kuziemski Information Technology, 2008. IT 2008. 1st International Conference on, 359-362, 2008 | 3 | 2008 |