Obserwuj
Diana Whaites PhD, CMPS, MACPSEM
Diana Whaites PhD, CMPS, MACPSEM
ICON Cancer Centres
Zweryfikowany adres z icon.team
Tytuł
Cytowane przez
Cytowane przez
Rok
Photon optimizer (PO) vs progressive resolution optimizer (PRO): a conformality-and complexity-based comparison for intensity-modulated arc therapy plans
D Binny, T Kairn, CM Lancaster, JV Trapp, SB Crowe
Medical Dosimetry 43 (3), 267-275, 2017
302017
Monitoring Daily QA 3 constancy for routine quality assurance on linear accelerators
D Binny, CM Lancaster, T Kairn, JV Trapp, SB Crowe
Physica Medica 32 (11), 1479-1487, 2016
292016
Effects of changing modulation and pitch parameters on tomotherapy delivery quality assurance plans
D Binny, CM Lancaster, S Harris, SR Sylvander
Journal of Applied Clinical Medical Physics 16 (5), 87-105, 2015
292015
A multi‐institutional evaluation of machine performance check system on treatment beam output and symmetry using statistical process control
D Binny, T Aland, BR Archibald-Heeren, JV Trapp, T Kairn, SB Crowe
Journal of Applied Clinical Medical Physics, DOI: 10.1002/acm2.12547, 2019
272019
Investigating output and energy variations and their relationship to delivery QA results using Statistical Process Control for helical tomotherapy
D Binny, E Mezzenga, CM Lancaster, J Trapp, T Kairn, S Crowe
Physica Medica: European Journal of Medical Physics 38, 105-110, 2017
252017
Investigating the use of aperture shape controller in VMAT treatment deliveries
D Binny, M Spalding, SB Crowe, D Jolly, T Kairn, J Trapp, A Walsh
Medical Dosimetry (in press), 2020
192020
Statistical process control and verifying positional accuracy of a cobra motion couch using step‐wedge quality assurance tool
D Binny, CM Lancaster, JV Trapp, SB Crowe
Journal of Applied Clinical Medical Physics 18 (5), 70-79, 2017
162017
Wearable glass beads for in vivo dosimetry of total skin electron irradiation treatments
SK Nabankema, SM Jafari, SC Peet, D Binny, SR Sylvander, SB Crowe
Radiation Physics and Chemistry 140, 314-318, 2017
122017
Investigating the use of image thresholding in brachytherapy catheter reconstruction
D Binny, CM Lancaster, T Kairn, JV Trapp, P Back, R Cheuk, SB Crowe
Australasian physical & engineering sciences in medicine 39, 913-919, 2016
102016
Tomotherapy treatment site specific planning using statistical process control
D Binny, CM Lancaster, M Byrne, T Kairn, JV Trapp, SB Crowe
Physica Medica 53, 32-39, 2018
92018
Radiotherapy quality assurance using statistical process control
D Binny, CM Lancaster, T Kairn, JV Trapp, SB Crowe
World Congress on Medical Physics and Biomedical Engineering 2018, 437-442, 2019
82019
TSET–TOTAL SKIN ELECTRON THERAPY, A CASE STUDY USING OPTICALLY STIMULATED LUMINESCENCE DETECTORS AND ITS BENEFITS
D Binny, C Lancaster, P Back, G Pratt
Australasian Physical and Engineering Sciences in Medicine, 2013
12013
Departmental action limits for TQA energy variations defined by means of statistical process control methods
D Binny, E Mezzenga, A Sarnelli, T Kairn, SB Crowe, JV Trapp
Physical and Engineering Sciences in Medicine 43, 29-34, 2020
2020
Retrospective analysis of three-year Tomotherapy Hi-ART output checks using statistical process control methods
E Mezzenga, D Binny, A Romeo, EML Neri, S Corelli, F Monti, ...
RADIOTHERAPY QUALITY ASSURANCE USING STATISTICAL PROCESS CONTROL, 122, 2019
2019
A multi-centre evaluation of Machine Performance Check (MPC) system on treatment beam output and symmetry using Statistical Process Control
D Binny, T Aland, BR Archibald-Heeren, T Kairn, JV Trapp, SB Crowe
RADIOTHERAPY QUALITY ASSURANCE USING STATISTICAL PROCESS CONTROL, 167, 2019
2019
Tomotherapy quality assurance using statistical process control
D Binny, CM Lancaster, T Kairn, JV Trapp, S Crowe
Accuray Symposium, Brisbane, 2018, 2018
2018
Investigating output and energy variations and evaluating effects of Dose Control System installation for helical tomotherapy
D Binny, CM Lancaster, T Kairn, JV Trapp, SB Crowe
Accuray Symposium, Sydney, 2016, 2016
2016
Acknowledgement of APESM reviewers for Volume 39
A Herrati, HR Abdul, MZ Abdul, H Acar, T Ackerly, SA Aghayan, ...
Australas Phys Eng Sci Med 39, 1191-1194, 2016
2016
Statistical Process Control and verifying positional accuracy of the HP cobra couch using step-wedge tomotherapy quality assurance tool
D Binny, CM Lancaster, JV Trapp, SB Crowe
Accuray Symposium, Sydney, 2016, 2016
2016
In-vivo dosimetry for total skin electron treatments using wearable glass beads
SK Nabenkema, D Binny, S Jafari, SR Sylvander, SB Crowe
Australasian Physical and Engineering Sciences in Medicine 39 (4), 1168, 2016
2016
Nie można teraz wykonać tej operacji. Spróbuj ponownie później.
Prace 1–20