Follow
Jaroslaw Filipiak
Title
Cited by
Cited by
Year
Experimental and numerical biomechanical analysis of vascular stent
W Walke, Z Paszenda, J Filipiak
Journal of Materials Processing Technology 164, 1263-1268, 2005
1162005
Fabrication of a polymer-based biodegradable stent using a CO2 laser
B Stępak, AJ Antończak, M Bartkowiak-Jowsa, J Filipiak, C Pezowicz, ...
archives of civil and mechanical engineering 14 (2), 317-326, 2014
772014
The effect of substrate roughness on the surface structure of TiO2, SiO2, and doped thin films prepared by the sol-gel method
J Krzak-Roś, J Filipiak, C Pezowicz, A Baszczuk, M Miller, M Kowalski, ...
Acta of Bioengineering and Biomechanics 11 (2), 21-29, 2009
682009
Mechanical, rheological, fatigue, and degradation behavior of PLLA, PGLA and PDGLA as materials for vascular implants
M Bartkowiak-Jowsa, R Będziński, A Kozłowska, J Filipiak, C Pezowicz
Meccanica 48, 721-731, 2013
492013
Oral administration of kaempferol inhibits bone loss in rat model of ovariectomy-induced osteopenia
B Nowak, A Matuszewska, A Nikodem, J Filipiak, M Landwójtowicz, ...
Pharmacological Reports 69 (5), 1113-1119, 2017
412017
Study of surface structure changes for selected ceramics used in the cad/cam system on the degree of microbial colonization, in vitro tests
M Dobrzynski, M Pajaczkowska, J Nowicka, A Jaworski, P Kosior, ...
BioMed Research International 2019, 2019
272019
Microhardness of human cancellous bone tissue in progressive hip osteoarthritis
M Tomanik, A Nikodem, J Filipiak
journal of the mechanical behavior of biomedical materials 64, 86-93, 2016
262016
The combined impact of mechanical factors on the wall stress of the human ascending aorta–a finite elements study
T Plonek, M Zak, K Burzynska, B Rylski, A Gozdzik, W Kustrzycki, ...
BMC cardiovascular disorders 17, 1-7, 2017
232017
Wall stress correlates with intimal entry tear localization in type A aortic dissection
T Plonek, M Zak, B Rylski, M Berezowski, M Czerny, F Beyersdorf, ...
Interactive CardioVascular and Thoracic Surgery 27 (6), 797-801, 2018
222018
Physicochemical and mechanical properties of CO2 laser-modified biodegradable polymers for medical applications
M Kobielarz, M Gazińska, M Tomanik, B Stępak, K Szustakiewicz, ...
Polymer degradation and stability 165, 182-195, 2019
192019
The Use of 3D Printing Technology in the Ilizarov Method Treatment: Pilot Study.
K Burzyńska, P Morasiewicz, J Filipiak
Advances in Clinical and Experimental Medicine: Official Organ Wroclaw …, 2016
172016
Clinical factors affecting lower limb torsional deformities treatment with the Ilizarov method
P Morasiewicz, J Filipiak, K Krysztoforski, S Dragan
Orthopaedics & Traumatology: Surgery & Research 100 (6), 631-636, 2014
172014
In vitro hemocompatibility studies of (poly (L-lactide) and poly (L-lactide-co-glycolide) as materials for bioresorbable stents manufacture
M Szymonowicz, Z Rybak, W Witkiewicz, C Pezowicz, J Filipiak
Acta Bioeng. Biomech 16, 131-139, 2014
162014
Application of generative technologies in the design of reduced stiffness stems of hip joint endoprosthesis
K Ścigała, R Bėdziński, J Filipiak, E Chlebus, B Dybała
Archives of Civil and Mechanical Engineering 11 (3), 753-767, 2011
162011
Laser-modified PLGA for implants: In vitro degradation and mechanical properties
M Kobielarz, M Tomanik, K Mroczkowska, K Szustakiewicz, M Oryszczak, ...
Acta of Bioengineering and Biomechanics 22 (1), 2020
142020
Biomechanical aspects of lower limb torsional deformation correction with the Ilizarov external fixator
P Morasiewicz, J Filipiak, K Krysztoforski, S Dragan
Annals of Biomedical Engineering 42, 613-618, 2014
142014
Experimental investigation of durability of transpedicular screw-vertebra connection.
J Filipiak, C Pezowicz
Ortopedia, traumatologia, rehabilitacja 6 (2), 213-221, 2004
142004
Experimental analysis of external fixators for femoral bone elongation
R Będziński, J Filipiak
Acta of Bioengineering and Biomechanics 1 (2), 91-105, 1999
141999
Laser Texturing as a Way of Influencing the Micromechanical and Biological Properties of the Poly(L-Lactide) Surface
M Tomanik, M Kobielarz, J Filipiak, M Szymonowicz, A Rusak, ...
Materials 13 (17), 3786, 2020
132020
Comparative analysis of the deformation characteristics of biodegradable polymers considered as a material for vascular stents
M Bartkowiak-Jowsa, R Będziński, J Chłopek, J Filipiak, B Szaraniec
Polimery 56 (3), 224-231, 2011
132011
The system can't perform the operation now. Try again later.
Articles 1–20