Jaroslaw Filipiak
Title
Cited by
Cited by
Year
Experimental and numerical biomechanical analysis of vascular stent
W Walke, Z Paszenda, J Filipiak
Journal of Materials Processing Technology 164, 1263-1268, 2005
1102005
Fabrication of a polymer-based biodegradable stent using a CO2 laser
B Stępak, AJ Antończak, M Bartkowiak-Jowsa, J Filipiak, C Pezowicz, ...
archives of civil and mechanical engineering 14 (2), 317-326, 2014
642014
The effect of substrate roughness on the surface structure of TiO2, SiO2, and doped thin films prepared by the sol-gel method
J Krzak-Roś, J Filipiak, C Pezowicz, A Baszczuk, M Miller, M Kowalski, ...
Acta of Bioengineering and Biomechanics 11 (2), 21-29, 2009
552009
Mechanical, rheological, fatigue, and degradation behavior of PLLA, PGLA and PDGLA as materials for vascular implants
M Bartkowiak-Jowsa, R Będziński, A Kozłowska, J Filipiak, C Pezowicz
Meccanica 48 (3), 721-731, 2013
402013
Microhardness of human cancellous bone tissue in progressive hip osteoarthritis
M Tomanik, A Nikodem, J Filipiak
journal of the mechanical behavior of biomedical materials 64, 86-93, 2016
232016
Oral administration of kaempferol inhibits bone loss in rat model of ovariectomy-induced osteopenia
B Nowak, A Matuszewska, A Nikodem, J Filipiak, M Landwójtowicz, ...
Pharmacological Reports 69 (5), 1113-1119, 2017
192017
Physicochemical and mechanical properties of CO2 laser-modified biodegradable polymers for medical applications
M Kobielarz, M Gazińska, M Tomanik, B Stępak, K Szustakiewicz, ...
Polymer Degradation and Stability 165, 182-195, 2019
162019
Experimental analysis of external fixators for femoral bone elongation
R Będziński, J Filipiak
Acta of Bioengineering and Biomechanics 1 (2), 91-105, 1999
151999
The Use of 3D Printing Technology in the Ilizarov Method Treatment: Pilot Study.
K Burzyńska, P Morasiewicz, J Filipiak
Advances in clinical and experimental medicine: official organ Wroclaw …, 2016
142016
Clinical factors affecting lower limb torsional deformities treatment with the Ilizarov method
P Morasiewicz, J Filipiak, K Krysztoforski, S Dragan
Orthopaedics & Traumatology: Surgery & Research 100 (6), 631-636, 2014
142014
In vitro hemocompatibility studies of (poly (L-lactide) and poly (L-lactide-co-glycolide) as materials for bioresorbable stents manufacture
M Szymonowicz, Z Rybak, W Witkiewicz, C Pezowicz, J Filipiak
Acta Bioeng. Biomech 16, 131-139, 2014
132014
Application of generative technologies in the design of reduced stiffness stems of hip joint endoprosthesis
K Ścigała, R Będziński, J Filipiak, E Chlebus, B Dybała
Archives of Civil and Mechanical Engineering 11 (3), 753-767, 2011
132011
Experimental investigation of durability of transpedicular screw-vertebra connection.
J Filipiak, C Pezowicz
Ortopedia, traumatologia, rehabilitacja 6 (2), 213-221, 2004
132004
Study of surface structure changes for selected ceramics used in the CAD/CAM system on the degree of microbial colonization, in vitro tests
M Dobrzynski, M Pajaczkowska, J Nowicka, A Jaworski, P Kosior, ...
BioMed research international 2019, 2019
122019
Wall stress correlates with intimal entry tear localization in Type A aortic dissection
T Plonek, M Zak, B Rylski, M Berezowski, M Czerny, F Beyersdorf, ...
Interactive cardiovascular and thoracic surgery 27 (6), 797-801, 2018
112018
Biomechanical aspects of lower limb torsional deformation correction with the Ilizarov external fixator
P Morasiewicz, J Filipiak, K Krysztoforski, S Dragan
Annals of biomedical engineering 42 (3), 613-618, 2014
112014
Comparative analysis of the deformation characteristics of biodegradable polymers considered as a material for vascular stents
M Bartkowiak-Jowsa, R Będziński, J Chłopek, J Filipiak, B Szaraniec
Polimery 56 (3), 224-231, 2011
112011
Popiół lotny w budownictwie. Badania wytrzymałościowe gruntów stabilizowanych mieszanką popiołowo-cementową
J Filipiak
Rocznik Ochrona Środowiska (Annual Set of Environment Protection) 13, 1043-1054, 2011
112011
Influence of loading history on the cervical screw pullout strength value
C Pezowicz, J Filipiak
Acta Bioeng. Biomech 11 (3), 35-40, 2009
102009
The impact of the type of derotation mechanism on the stiffness of the Ilizarov fixator
P Morasiewicz, J Filipiak, M Konietzko, S Dragan
Acta Bioeng. Biomech 14 (1), 67-73, 2012
92012
The system can't perform the operation now. Try again later.
Articles 1–20